Dear Members,
In Centrifugal Compressors we calculate Polytropic efficiency only -Why not adiabatic efficiency ?
Where we calculate and use adiabatic efficiency?
Thanks in advance.
DEAR 25362,
With floating end you are correct(no one will like the floating end nozzle extending through the rear end cover in an odd pass STHE).
In the case of fixed tube sheetSTHE, is there any advantage in having both tube-side inlet and outlet piping connections at the same end.
Dear members,
Though add no of tube passes are not unknown, most STHE have an even number so that both tube-side inlet and outlet piping connections are made at the same end.What are the advantage?
Thanks in advance.
Dear friends,
The following are the equations:
Page : 106 The following common equation is used for both desuperheating and condensing.
1 1
---- = ---- + ro
U(dir) ho
Page 58 / Page 62:
1 1 Lw { Ao } 1
---- =...
Dear members,
In March 1981 issue of HYDROCARBON PROCESSING page 135, an example is given for partial condensers. Some-one could clarify what is the dry gas flow and dry gas molecular weight. The gas stream is being natural gas how molecular weight could be 36.7 against natural gas molecular...
Dear members,
As in page no- 62 of Applied process design for chemical and petrochemical plants by E.E. Ludwig volume three, how to incorporate tube material thickness and conductivity in the worked out example in page no-106(Condensation in the presence of non condensables).Any suitable...