  • panter
    panter replied to the thread Commutator marks in DC Motors.
    It should be noted that type and construction of the brush has not changed. A sandwich brush could reduce the problem with this problem...
  • panter
    panter replied to the thread Commutator marks in DC Motors.
    Additionally, I would check the tightness of the screws holding the main and auxiliary poles and measure the air gap between the rotor...
  • panter
    To begin with, you would have to measure resistance of the winding and compare it with the values from generator test sheet. As it is...
  • panter
    GR8blu , It seems to me that you are right. I predict that the first 6 PT 100 detectors are two per stator phase. Last two could be for...
  • panter
    panter reacted to Gr8blu's post in the thread Surge diverter in RTD terminal box with Like Like.
    My best guess: "SD" stands for "stator detector". The OEM did a poor job of identifying terminals on their wiring diagram. What they...
  • panter
    panter replied to the thread Generator with low IR.
    It is interesting that the resistance of the phase windings to ground is less than the phase-to-phase resistance. Generator is small and...