Hello All,
API 653 9.10.2.4 states: "Installation of a new tank bottom, after removal of the existing tank bottom, shall meet all requirements of API 650". That is exactly my case, I have an old tank whose tank bottom is being replaced. Questions: 1. All the NDE required by API 650 apply in...
Thank you very much JStephen, now I think things are more clear to me, the sketch you attached helped me so much. But I still have a doubt: that mean that for riveted thanks I have to calculate 2 minimum thicknesses, one for the locations within the 6 in. of rivets using E according Table 4.3...