Thank you for the answer,
As per the stability analysis for a small dam with 15 m high;
the following soil parameters seem to be enough:
bearing capacity: 300 kPA
coefficient of frinction: 33 degree
cohesion:100 kPa
At this point, how can I specify the jet grouting parameters?
I read some...