Proper operating temperature for servo hydraulic systems (3000 PSI system pressure) has always been a debate around here. If you look a Moog specifications, you'll find that their valves are good up to 275 deg F. When you look up specs for Mobil DTE 25, the viscosity charts suggest temperatures...