Electricpete,
The motor in question is a Westinghouse 5010H 2 pole motor full load stampled speed is 3553 RPM. It would be valuable to take a high resolution look at the lower frequencies. I do have a question though in terms of the extent of slip speed as the motor is being shop tested...
For MikeHalloran:
I asked the same question about the end bells being swapped end for end and the shop adamantly said it was not the case.
For spciesla:
The way this motor is set-up is you actually have the ball bearing floating axially in the end-housing. There is a radial clearance...
I'm still confused how you get misalignment when the machine is running uncoupled in a shop. Plus the housing and journal work was done in September and it passed a run test in shop so I’d be suprised if it were misalignment due to improper machining/fits. Only after are we changed out the...
I apologize in advance for the long post.
I have a 4160V, 650 HP Motor(AC,Ind.) which is experiencing some vibratory difficulties...
History:
Motor had initially wiped bearings (deep groove ball bearing which free float axially in the end housings), journals and the bearing housing...