Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations JAE on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by Nev80

  1. Nev80

    BYSTRONIC 3015 WATERERROR

    after turning the flow meter knob to the maximum, the waterflow went from 65 to 68 ... but still in watererror
  2. Nev80

    BYSTRONIC 3015 WATERERROR

    the waterflow is correct (65) ... no, I did not see any loss of power
  3. Nev80

    BYSTRONIC 3015 WATERERROR

    in winter, it works correctly ... in summer, it works normally for 1 hour or 2 ... then goes into watererror..I let the temperature go down again ... it works again for 5 or 10 minutes then goes back to watererror
  4. Nev80

    BYSTRONIC 3015 WATERERROR

    BTL 1800 turbo
  5. Nev80

    BYSTRONIC 3015 WATERERROR

    Hello We Have a laser BySprint 3015 with a cooler (ep cooling WKLI80) He gets watererror in summer or when it's hot in the factory Thanks for help Best Regards