  1. muksidin taslim

    Temperature high, the compression can not reach the design point pressure

    Thank for the answers, So far we check the opening of bypass valve is okay same as on DCS screen. This compressor is Recycle Nitrogen Compressor (RNC) to provide High Pressure Nitrogen to Turbo Expander. The source Nitrogen in suction is divided into 3 lines, from discharge turbo expander, N2...
  2. muksidin taslim

    Temperature high, the compression can not reach the design point pressure

    Hello ... In our plant, our compressor machine can not reach the design point pressure, our team has performed to evaluate it. The IGV opening, pressure & temperature suction seem normal as usually. But the difference conditions are the temperature after 1st stage, 2nd stage and 3rd stage...