The stiffness of a flange is related to the stiffness of the bolted joint. this means that Km is related to Kb. the formula can be located in any engineer's design handbook. the most common one is by Shigely. Just in case you cannot find it the formular for Km is given as
Km=dAE e(b(d/lm)