Assuming the system is closed, if all the contents are transferred via vacuum/pressure will the tanks (pressure/vacuum) equilibrate to 0 psig?
I’m asking this with respect to the amount of space under vacuum and the amount of space under pressure at the end of the transfer
I will need ½ negative atmosphere in the destination tank and ½ an additional positive in the source to move all the contents after the level in both tanks have equilized.
Looking at screwli9ft systems and steam air ejector that discharges to source vessel.
This material is essentially polymer globule in water it cannot be “pumped” until it is fully reacted and stabilized.
Sure, I can pressurize the source tank but a some point I'll have to relieve the pressure in that tank - that's the problem.
I don't want to have to vent off VC laden vapor
I...
Problem:
Transfer 10k gallons of contents from one tank to another tank in 20min.
With contents velocity not exceeding 10ft/s
Assumptions: (Tanks and piping)
Both source and destination tanks have 11’ dia and 15’ straight side with ASME dish top/bottom heads rated at 75 psig / full...