Hi,
We regularly use A320 L7 Bolts in our work for load bearing connections, but am I right in saying that standard 8.8 bolts aren't actually that far off L7 bolts in terms of strength and 10.9 or 12.9 are actually stronger?
Thanks.
Thanks for all the responses, you have been a great help. I think that this forum was porobably the wrong one for the pump question as you possibly don't quite understand the application of the pump I am using. Thanks for trying to help though.
mechmos
Thanks for the responses, yes I did mean too low for 21.519.
I should maybe have explained the application, it is for oilfield use and yes we just directly couple the triplex pump to the transmission via a driveshaft. The pump is capable of pumping water to 20,000PSI.
Dicer I am intrigued as to...
Thanks Norm,
That helps on the first question. It is still high for the HT700 series with a first gear ratio of 7.97 but it makes a lot more sense than 21.519.
Thanks
Hi,
I am looking into the compatibility of pumps and engines and am struggling to get my head around the torque issue. Two questions really, firstly the transmsission. I am considering the Allison HT700 series and in the handbook it states that the overall torque multiplication is the product...
I have been asked by someone in my company to look into what grade of either super duplex or inconel they will need for pipe for pumping 10%HCL at 90 degrees centigrade.
Any advice as I have not had experience of either of these before?
Greatly appreciated.
Mechmos
Thank you both for the advice,
I wasn't sure if that was the case or not, i will get in touch with the PTC sales rep and find out what the story is.
Thanks again,
Mechmos
Hi,
This is a bit if a strange question and a bit of a long shot but I was wondering if anyone knew where the best place to sell a second hand license of ProE wildfire is.
My company bought it last year for an engineer who has since left the company and we no longer have a need for it, the...
Hi,
I am trying to write a procedure for my work regarding the noise at work regs and i am wondering if there is a standard way of measuring or it is totally up to the individual company? The piece of equipment i am trying to measure is a containerised pump unit which will contain a large...
I am looking for anybody that may be able to tell me or point me in the right direction of finding the allowable stresses of 8630 mod. steel at room temperature and at an elevated temperature of 100 Degrees c.
Thanks
HI,
I'm looking for some guidance as to what standards to look at for the procedure and safety of hydrostatic pressure testing of a triplex pump with an operating pressure of 11200 PSI?
From looking at previous threads people have been discussing ASME B31.1 an BS EN 12162 but without copies of...