Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by Max1976

  1. Max1976

    Centrifugal Pump Head

    Deear All, Thank you for the contributes; the problem was a real gardening problem, however data are not available; If you like, consider the following pump as reference: Output: 1 HP, Outlet: 2" Rated: H 7.5 (M), Q 220 (L/M) Maximum: H 12 (M), Q 450 (L/M) Dimension: 350 L x 162 W x...
  2. Max1976

    Centrifugal Pump Head

    Thanks for the contributes, I don't have specific data for the garden pump: Supposing the following partial further information available: Impeller Diameter: 200mm Number of Vanes: 10 Approach Angle of Vanes:5% Numero di stadi:1 Many Thanks, Max
  3. Max1976

    Centrifugal Pump Head

    Thank you for your answer. The head so evaluated is anyway inclusive of the ( garden-hose )pressure losses. Thanks, Max
  4. Max1976

    Centrifugal Pump Head

    Thank you for your answer; There is the need of a further clarification: my question is how to evaluate a priori if the pump can do it ( given the flow-rate )? Thanks Max
  5. Max1976

    Centrifugal Pump Head

    Dear All, More than a process engineering question, it could be considered a gardening problem. How to determine the Centrifugal Pump Head for a given flowrate without using a Pressure Gauge? ( Characteristic Curves are not available ) Best regards, Max
  6. Max1976

    Wall Vessel Temperature after BDV Gas Depressurization

    In order to apply the suggested criterion, how can I quickly estimate the rate of change of the temperature?
  7. Max1976

    Vessel Wall Temperature after Gas Depressurization trough an orifice

    I would be interested in knowing both the cases: 1) No Heat Trasfer to Fluid ( is there an analytical solution ? ) 2) No heat transfer from the outside surroundings thanks
  8. Max1976

    Vessel Wall Temperature after Gas Depressurization trough an orifice

    Dear All, I need to determine the Vessel Wall Temperature after Gas depressurization trough an orifice ( API 521 ) and to verify the necessity of applying Low Temperature Carbon Steel. I know the possibility of using Hysys ( ASPEN Tech. )Depressurization Utility, however I have the following...
  9. Max1976

    Wall Vessel Temperature after BDV Gas Depressurization

    Dear All, I need to determine the Wall Vessel Temperature after Gas depressurization trough an orifice ( API 521 ) and to verify the necessity of applying Low Temperature Carbon Steel. I know the possibility of using Hysys ( ASPEN Tech. )Depressurization Utility, however I have the following...