dear 25362,
thanks very much for ur valuable contribution, i just want more elaboration on the below,if you have a time,:
1- once-through thermosiphon reboilers
2- In these cases, a valved start-up line is generally provided from the bottom of the column.
thanks again
Hi all
regarding the title, it is a naphtha stabilizer column which separate LPG from hydrotreated naphtha with a bottom temp. of 176 deg C at the reboiler draw-out and 190 deg C at the reboiler return.
the feed flow into this column is ranging from 24~35 ton/h
* my question is why the reboiler...
thanks JJPellin for your comments
yes we plan to send a sample to a third party lab. to specify the problem.
you are right, theoe pictures were taken just as the piston was being extracted from the cylinder.
in one of the photos and under the feet of the persons you can see the rubber rings...
hi all
we face a very strange crack of a reciprocating H2 compressor K-202 @ CCRU which deliver produced H2 to all users.
vendor's investigations reveal nothing.
any idea or similar case?
here is the photos
https://picasaweb.google.com/mahmmoud30/ReportAboutK202?authkey=Gv1sRgCIWfla_lxazGlwE#
hi all
i want to know why
1. Atm. distillation columns have constant diameter from top to bottom while lighter cuts (e.g diesel ,naptha..etc have variable diameter from bottom to top?
2. why some absorbers are wide at top and narrow in the bottom?
hi all
I just want to know why the reading of a vibration sensor is in -ve volts, and could it read in +ve and what is the reference of -ve or +ve?
regards
thanks maddocks for your replay and I'll try to find the mentioned simulator. yes as you said, I use mccabe thiel only for acaimic purposes not actual practice.
thanks again
hi all
i want to design distillation column to separate c3 from c4 but i didn't find VLE data so as to apply mcab-thiel procedure.also if there are special design equations regarding the liquified gases please hepl me.
thanks alot
Hi all
I am a little bit confused about these two terms:
1. codes (e.g vessels design codes)
2. standards (e.g vessels design standards)
so plz can somebody explain more!!
thanks alot
thank you dcasto
about using DP to detect flooding plz see the attached filehttp://files.engineering.com/getfile.aspx?folder=2cfe4770-954b-4fd1-8965-c3d743b4b648&file=3051S_ASP_Distillation_Column_Flooding.pdf
thanks JJPellin for this rich response. we are in a very hot country and this case happed at midnoon.
we have local hand-off-auto swith near the aux pump which was in auto mode, is it the same as the auto-start switch that can be set up as latching or not latching or you mean something else...