  1. magreen

    Two Control OIl Pumps with Differerent Capacities on CO Unit

    byrdj: Your colored lines are all correct. The question mark is a level transmitter. The data come from the mfr's data sheet. Physically, Pump No. 2 is bigger and a bit heavier (20%), with higher flow rate (30%). JJ Pellin: The two pumps run with the same rpm.
  2. magreen

    Two Control OIl Pumps with Differerent Capacities on CO Unit

    byrdj: Thank you for your response. Please see the attached P&ID of the CO Unit that provides answers to part of your questions. In reply to your questions regarding logic: (1) Each pump can be stand-by for the other. (2) There is no priority for start/run for pump A or B. (3) It seems there...
  3. magreen

    Two Control OIl Pumps with Differerent Capacities on CO Unit

    Hi, On a chemical plant, there is a steam turbine generator package with a LO Unit and a CO Unit. On the CO Unit, there are two pumps (variable volume piston pumps) with different capacities. Until now on all the plants that I have seen, all the pumps on LO units and CO units were identical with...
  4. magreen

    Straight Length Before and After Strainer at Steam Turbine Inlet

    byrdj & JJPellin, The strainer is a common cone type one and not special, not cyclone type. Thank you all.
  5. magreen

    Straight Length Before and After Strainer at Steam Turbine Inlet

    Hi, A manufacturer of steam turbine requires a long straight length at upstream and downstream of a strainer at steam turbine inlet. The turbine is about 14MW and steam flow is about 85t/hr. Size of inlet pipe is 8in. The length of strainer is 650mm. The manufacturer requires 2500mm straight...
  6. magreen

    Connecting Flanges with Different Facings

    Is it allowed by ASME B16.5 to connect two flanges of different facings, say, Flat Face to Raised Face or to Lap Joint? If it is allowed only under some specific conditions, what are those conditions? If not allowed what is the technical reason for that? I appreciate any advice.
  7. magreen

    Gantry Crane Normal Modes of Operation

    Thanks kingnero for having your opinion.
  8. magreen

    Gantry Crane Normal Modes of Operation

    Hi, For the design of a gantry crane I need to know what is the normal mode of operation actually used by crane operators. The crane capacity is 25tons, with height of 15m and a total span of 52m and 32m span between the two legs. I would like to know if it is normal for operators to lower or...