Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by lucas2008

  1. lucas2008

    Fac in CAESAR II

    Thanks richay. This pipeline aren´t overstressed , but i want to make the calculation memory and i must to write this FAC. the data in this memory. Thanks again
  2. lucas2008

    Fac in CAESAR II

    Thank richay for the answer. I run the buried model with FAC blank, but in the CAESARS'Quick reference guide for B31.4 indicate: 1- If FAC = 1 (fully restrained pipe) 2- If FAC= 0.001 (buried, but soil restraints modeled) 3- If FAC=0.0 (fully above ground) I use the case 2. however, if I...
  3. lucas2008

    Fac in CAESAR II

    I am doing a analysis for the underground pipeline and I have few soil data. I will use the following soil data: friction angle : 27 density: 1.8 kg/m3 coeff. friction: 0.2 Soil : sand OCM:6 I specified ALLOWABLE STRESSES B31.4 (2002) Eff= 1.0000 Sy= 241,316 KPa Fac= .5 I need to...
  4. lucas2008

    Compressor shut Down

    Sorry, I speak spanish and I can hardly speak english . But I will try to explain you. On reciprocant compressors,where the type contol capacity is manual variation speed. i.e. the capacity is controled by operator, he actuates the fuel- admission valve on the compressor driver to control...
  5. lucas2008

    Compressor shut Down

    The Overspeed in the driver, gas drive, became as a result shut Down in the sucction line of reciprocant compressor. Is it possible?