Thanks Blas
I did rebuilt the result shows "ok to delete unreferenced solid geometry? your model constrains invalid geometry that can not be used" I choose ok, then all the surfaces gone. the file has been attached, can you help to take a look.
Thanks
Lihua...
Thanks Thomas
i do run linear analysis ,Like say i have Load case1 - FX; Load case 2 - Fy; Load case 3 Fz; then i need the conbined load 0.2*Fx+0.3*Fy+0.4*Fz. What i do is go Menu Model/Load/Combine. but i do like this, when i change basic load case data, i need to re-combined them again. you...
Thanks Thomas
i do run linear analysis ,Like say i have Load case1 - FX; Load case 2 - Fy; Load case 3 Fz; then i need the conbined load 0.2*Fx+0.3*Fy+0.4*Fz. What i do is go Menu Model/Load/Combine. but i do like this, when i change basic load case data, i need to re-combined them again. you...
How to update the combined load automatically when the basic load case changed in Femap. so that i dont need to re-combined again when the basic load changed.