Does anyone know if a rupture disc can be installed at a larger distance from PSV ?
I am thinking of installing a rupture disc on a STHE-2 (see the sketch), which is not in use on shell side and hence empty, but still being used on tube side. So a tube rupture case is valid.Presently...
thanks everyone for their reply.
The app is for gas phase (mostly air with around 100-300 ppm of VOCs) ,24/7 operation.
Other thing is , the air is totally saturated with water vapor .
Based on preliminary sizing, looks like 2 m in diameter and 3-4 m in height(for 12-14 weeks of service).
We...
Hello,
I have a total condenser (inlet 100 % vapor - Outlet 100% Liquid), where based on design pressure ratio of Shellside/Tubeside, the catastrophic tube rupture is a valid case.
Now , if the fluid is 100% vapor on both side or 100 % liquid on both side or 2-phase on both side, I know how to...
Hello,
Does anyone has experience with activated carbon bed installation?
we are doing some investigation of carbon bed and my question is , can it be installed outdoors where ambient temperatures can go as low as -40 deg C ?
thanks
Sorry...the link is not working. I will upload it......http://files.engineering.com/getfile.aspx?folder=72dc2393-de04-412e-aac0-0e72014a9c5b&file=adsorption.ppt
your heat generation in he bed will depend upon type of contaminants in air.Each specie will have a different heat of adsorption.
I believe, if your air flowrate and VOC concn vary constantly,it would be difficult to come at a perticular number of flow...
Best you can do is keep a certain...