Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by Kunal_88

  1. Kunal_88

    How to increase time increment for a dynamic explicit analysis ?

    Do you think that reducing the mesh size after 2mm will help as accuracy is also a matter of fact. If I reduce step time then my speed and workpiece dimension will also need to change and will ruin the model. Can I use any other method like other than explicit to make the process faster.(I am...
  2. Kunal_88

    How to increase time increment for a dynamic explicit analysis ?

    Hello. I am simulating friction stir welding with Abaqus dynamic explicit and CEL technique. I have taken tool as rigid body and uniform mesh size of 2mm. Stable time increment is coming out to be 1.7 *e-7 and total time for simulation is 120s. I have tried mass scaling but due to ridid body of...