Recent content by KMur

  1. KMur

    Cladding vs Overlay for Sour Service

    Yes nickypaliwal. SSC is required. HIC is not required.
  2. KMur

    Cladding vs Overlay for Sour Service

    in this case, parent metal need to be SSC tested or SSC resistant quality plate is required, but HIC tested is not required.
  3. KMur

    Test Separator for Produced Water

    Its depends on composition and process parameters. We are using now Carbon steel+3mm CA with Phenolic Epoxy lining for separators. we used CS+cladding also.
  4. KMur

    Corrosion and Scale

    Dear friends, Presently I am working for effluent water treatment plant which contians Balance tank, IGF units and Nutshell filters etc.. I have to prepare corrosion and scale assessment study. Please provide me the guidelines or any documents to know the corrosion mechnisms in this plant. Thanks
  5. KMur

    Trim material selection

    Thank you SJones. Valve body material is CS. We are selecting the material based on ISO 15156 part 3.Finally, Inconel 625 is selected as trim material. thanks
  6. KMur

    Valve trim material

    I got a message to mail that cassiel(industrial) has responded to this thread. But I didn't get reply .
  7. KMur

    Trim material selection

    Dear All, Crude details are as follows: Pressure = 55 psig, H2s mole fraction = 0.0011 and partial pressure of H2S = 0.07667 psia, NACE Sour = YES and Formation water analysis: Chloride content = 161500 mg/l and pH=5.7 Please suggest me how to select valve trim material based on NACE MR 0175?
  8. KMur

    Valve trim material

    Dear All, Crude details are as follows: Pressure = 55 psig, H2s mole fraction = 0.0011 and partial pressure of H2S = 0.07667 psia, NACE Sour = YES and Formation water analysis: Chloride content = 161500 mg/l and pH=5.7 Please suggest me how to select valve trim material based on NACE MR 0175?
  9. KMur

    the requirement for internal coating

    Dear all, please advise me for the requirement of internal coating of gas induced flotation tank. This is 100 MBPD capacity tank.
  10. KMur

    corrosion inhibition points

    Thanks to all. Yes. Eventhough Export oil is not corrosive since it was treated, our PMC people are forcing to keep more than one injection point since they are expecting more corrosion without any reason. We have to fulfil their requirement or need to give justification that one point is...
  11. KMur

    corrosion inhibition points

    Dear brimmer, Thank you very much. How can I get the residual chemical concentration? Can I get from chemical supply vendor? Please suggest me.
  12. KMur

    corrosion inhibition points

    Dear all, In oil export pipeline (120km length), at present we are injecting corrosion inhibition at starting point of pipeline. Client wants to add more injection points , is there any basis to add these points based on length?, Please provide any standard to implement these points. thanks
  13. KMur

    material selecion for drum

    Dear Weldstan, Co2=2% and H2o=1%. no data about chloride content. What type of coating is suitable here? I am thinking for Cladding. Otherwise. CS+6mm CA and internal coating. Please suggest me for coating. Thank you
  14. KMur

    Effect of methanol in co2 corrosion

    Dear All, We are using methanol injection to avoid hydrate formation in sweet service. Is this effect on Co2 corrosion? CO2 corrosion rate is decreasing by adding glycol concentration. I want to know the effect of methanol in co2 corrosion? Please clarify. Thanks