I agree with kenmac777. We specialize in API Storage Tanks, and we typically design condensate tanks with A36 w/ internal lining. The lining is usually epoxy coating.
Gentlemen,
We are looking into building a vessel 28 feet in diameter x 308 feet tall out of SA-537 Gr.2 material 1 ¼” thick. The design temperature is -50°F so the material will require impact testing. Will heat treating be required by the ASME Code?
Thanks...
Hello All,
My company is currently fabricating three LNG Tanks, and the temperature can reach -265 Deg. F. I am in the process of trying to purchase some 4" and 6" 150# Flanges that would be good for this temperature. Some of the Flanges will need to be Stainless Steel, and some are...
Thanks metengr,
I thought that was were I should be looking, thanks for putting me on the correct path. My only problem with using ASME Section II, Part D, Table 3, is that it does not give you the lowest temperature that the material can be used, it only starts at -20 Deg. F. I know...
Gentlemen,
Does anyone know if a 2006 Addenda has been issued for ASME BPVC Section VIII, Divsion I, 2004 Edition? And if so, where can I find a copy? Thanks... Also, if I have a shop that is getting a vessel U-Stamped to the 2006 Addenda, but the COMPRESS calcs do not have the 2006...
Gentlemen,
Does anyone know of or have a design standard they use when deciding whether to use a 2:1 Elliptical Head or an F&D Head in their design? I know 2:1 Elliptical Heads are usually used for small and medium diameters, and higher pressures. And F&D Heads are usually used for lower...
Gentlemen,
Does anyone know of or have a design standard they use when deciding whether to use a 2:1 Elliptical Head or an F&D Head in their design? I know 2:1 Elliptical Heads are usually used for small and medium diameters, and higher pressures. And F&D Heads are usually used for lower...
Hello All,
I am in the process of designing a Sour Water Stripper that is 6'-0'' I.D X 95'-0'' T/T, and all the nozzles have external loads. I have a few questions regarding the Warnings/Defeciences Report, if anyone has experienced the same issues.
1. For one of my Nozzles located in...
Hello All,
During the forming process of ASME Heads, where does the most Thin-out occur? Or what area of the Head will see the highest stresses? Thanks....
Hello All,
Does anyone know if it is a good practice to include Nozzle Loadings for Flange Ratings? What I mean is, in COMPRESS there is a check you can perform that will include external nozzle loadings in the Flange Rating. Or it will also use the Nozzle Loadings to limit the MAWP...