  1. JOM

    Brittle Failure of Vessels

    Hi MJC. I'm sure the tecnical understanding of brittle fracture resides in the forums you've suggested, but I think it is important that knowledge of the phenomenon of brittle fracure be widely known. Operational people need to know of it. It shouldn't be secreted away in a specialist arena...
  2. JOM

    what is "thermosyphon" in connection with a reboiler?

    Yes, with zero static head difference to induce flow, could thermally induced flow take over causing reverse flow through convection? It doesn't really matter, 25362. The heat to the HE had been shutdown anyway. I just wanted to get the thermosyphon process clear in my head. You've all helped...
  3. JOM

    what is "thermosyphon" in connection with a reboiler?

    Hi Milton. Yes, I believe I understand things correctly. I'm examining the details of an accident that involved an absorber where the condensate level in its bottom was not under control. The investigation report is in the public domain. I don't represent any party. The condensate level rose...
  4. JOM

    what is "thermosyphon" in connection with a reboiler?

    "JOM, is the HE a reboiler as the post heading suggests ?" Great question. I've wondered about the definition of reboiler. My impression is it's a term liberally used for any HE at the base of a tower. This one has been called a reboiler. In this case, the tower is an absorber. Condensate...
  5. JOM

    what is "thermosyphon" in connection with a reboiler?

    Thanks All. That Wikipedia link was useful, Milton, thanks. This has helped me. The case I was looking at involves liquid leaving the bottom of the tower to an exchanger and then re-entering the tower sump. So the flow is downwards. So thermosyphon (correct spelling, BTW) can't be involved as...
  6. JOM

    what is "thermosyphon" in connection with a reboiler?

    I've come across ther term "thermosyphon" in connection with reboilers on columns. I guess it implies flow of liquid induced by thermal gradient or something... Can anyone give me a simple but correct explanation of "thermosyphon"? John. J.
  7. JOM

    Room for field operators

    I cannot give you the answer, but would like to point out a couple of matters revealed by actual accidents. The US CSB last week presented its report into the Texas City accident. They said that persons in a flimsy building such as a trailer could be at greater risk compared to standing in the...
  8. JOM

    Blast Proof Modulars in Chemical Plants

    Maybe the fundamental question is why the personnel were located at this place. Was it essential or merely practical? Perhaps we'll learn more when the CSB release their final report. J.
  9. JOM

    Control room as refuge in emergency - wise?

    BigInch, Yeah, I think the discussion helped to show up the conflicting purposes of a CR and a refuge. J.
  10. JOM

    Control room as refuge in emergency - wise?

    epoisses, I'm not advocating that doors be barred and entry prohibited during an emergency. Heck, no. I'm thinking in terms of design and planning. Maybe the control room function and safe refuge should be separate design goals. I've found an incident where 50 people came to the control room...
  11. JOM

    Control room as refuge in emergency - wise?

    Lots of interesting comments on this topic. Thanks. Can I reduce this "issue" to something simple? What's the purpose of a control room? To control the plant. Does that change in the case of an emergency? Course not. So why use the control room as a mustering point? Why? Someone has said...
  12. JOM

    Control room as refuge in emergency - wise?

    G, Thanks for the lead on EERA. I see there are many publications about this. Good material. Mostly focussed on offshore. I'm more interested in land-based facilities. Offshore is a very special kind of workplace. I'll have a look at Lees. Do you think it would be useful to have reports on...
  13. JOM

    Control room as refuge in emergency - wise?

    G, "With modern instrumentation and CCTV systems there is no real need to have the control room located inside the plant. Locating it at some distance is an inherently safe approach" In which case, it can no longer be a mustering point, can it? Where would field personnel muster in an...
  14. JOM

    Control room as refuge in emergency - wise?

    Guidoo, What about fumes or gases entering through the instrumentation dusctwork? I know cables should have glands and seals but there are cases where gases entered the room. Do people validate the integrity of these entry points a matter of routine? (Incidentally, the Browns Ferry nuclear...
  15. JOM

    Control room as refuge in emergency - wise?

    schnipp, So, in your case, I think you're saying the personnel take refuge in the control room building but not in the actual control room. That would allow operators to continue with their control duties unimpeded. With the case I mentioned, the plant fire burned instrumentation wiring and...