    MPC Beam designation

    From SoCal mall drawings around 1980: MPC designation is for Marcrest built-up wide flange beams. From those drawings, MPC16X20.2: h=16.25" tw=0.185 bftop = 4" bfbot = 5.75" tftop = .312" tfbot = 0.312" Hope this helps.