A cyclone is used to measure repirable dust. When using a cyclone make sure that you have the pump set to the proper flow. Cyclones are calibrated to a certain flow rate.
The way a cyclone is used for respirable dust is it spins the air/dust entering like a cyclone dropping the large...
My company uses Ansell SolVex (nitrile) gloves for cleaning. I need to get Breakthrough data for these gloves, but Ansell does not give data for Sodium Hypochlorite (bleach). What do other workplaces do to provide data on breakthrough and permeation? Is there a good third party sorce that I...