Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by Iga2016

  1. Iga2016

    How to determine industrial user natural gas design load (Coincidence factor)

    Designing Natural gas industrial users metering and regulating station, for years I have been using a rule I found in a Dresser meter brochure to determine the industrial design load. This rule considers a coincidence factor that decreases with the number of connected equipment. See below Qty...
  2. Iga2016

    Maximum velocity natural gas pipeline tap

    Thank you for your response, I have found very valuable information in this site and it is the first time I ask for advice My case is as following I have an existing 2" tap where the gas consumption will increase in the near future Minimum main pipeline operating pressure: 476 psig Excepted...
  3. Iga2016

    Maximum velocity natural gas pipeline tap

    What is the maximum velocity that should be used to determine the diameter of a tap on a natural gas pipeline. We use 60 ft/sec as maximum velocity for the pipeline itself, Is there a diffrentet condition for the tap itself? Thank you