Recent content by hrbrt372

  1. hrbrt372

    Slenderness ratio requirement for compression members in AS4100

    Hi, Is there a recommended slenderness ratio in AS4100 for compression members, similar to AISC's kl/r <=200 for compression members? I have a 12m -200UC52 interior post that works with strength as the load is too little, only about 90kN. Thanks, Herbert
  2. hrbrt372

    Wind loads for Exposed portal frame per 1170.2-2011 Appendix E

    Thanks for the reply asixth. I have 16off portal frames and each portal frame has cfig1 = 2.05. On equation E2(5) in AS 1170.2 Cfig is equal to the summation of Cfig1 of each portal frame.
  3. hrbrt372

    Wind loads for Exposed portal frame per 1170.2-2011 Appendix E

    Hi All, I am currently working on a project to be built in Darwin. It is a skillion roof structure with no walls, 42m wide x 105m length with 6m clear height at the low side. It has 16 portal frames spaced at 7m and a 800WB member size. Following the guidelines listed in Appendix E of 1170.2...