    gte447f replied to the thread Whats the deal with hip roofs.
    Sadly, modern builders where I am from (American south) would never do this these days, because they couldn't wouldn't spare the cost of...
  • gte447f
    gte447f reacted to JAE's post in the thread Whats the deal with hip roofs with Haha Haha.
  • gte447f
    gte447f replied to the thread Steel Exposed to Fire.
    Well @phamENG is a concrete guy, in that they are a structural engineer who has studied concrete as a building material and probably...
  • gte447f
    gte447f replied to the thread How to fix this?.
    This seems to me to be a very strange way to look at your engineering duties, but taking it as a given, how does empowering them to do...
  • gte447f
    gte447f replied to the thread HOT TUB - gut check.
    OK, I'll give you that one. Coastal and certainly marine environments are a severe exposure category, so a special case where special...
  • gte447f
    gte447f replied to the thread HOT TUB - gut check.
    Seriously? Have you ever actually used this detail or did you just throw that out on the fly? That's a lot of fabrication to achieve...
  • gte447f
    gte447f replied to the thread HOT TUB - gut check.
    You may well be right, but just don't mix the materials seems like better advice. Reality check for this entire thread, go with hot dip...
  • gte447f
    Not sure about @XR250 , but I have seen shallow steel flush beams in residential construction just sitting/bearing on the wall top plate...
  • gte447f
    I agree in principal, but lets be honest, in reality there will be practically no shear in that diaphragm ever, and the rafters alone...
  • gte447f
    Personally, I would prefer your original design to bolt a shelf angle to the wall framing, although I can see the mason's reluctance due...
  • gte447f
    Well, I doubt these low roof diaphragms have been designed to transfer out any shear at the boundary, but if they had, that would be the...
  • gte447f
    gte447f replied to the thread Easy foundation work or a trap?.
    Not surprised. None of it happens here either for residential underpinning and it is a booming business here, but then again there is...
  • gte447f
    gte447f replied to the thread TJI Issue.
    @XR250 I understand where the homeowner and you are coming from, but in my opinion you haven't yet actually established that there is a...
  • gte447f
    gte447f replied to the thread Easy foundation work or a trap?.
    I can think of an obvious reason. Helical piles are beyond the scope of the IRC., and the IRC says that anything beyond the scope of...