Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by grvldrvr

  1. grvldrvr

    Calibration Standards

    Back on March 7, Andy981 states that in the case of +/-.005 tolerance, the 4:1 ratio would apply to .005 for an accuracy requirement of .00125. I have always thought the 4:1 ratio applies to the total tolerance, or .010 in this case, giving an accuracy requirement of .0025. Comments? Thanks SMR
  2. grvldrvr

    Concentricity again

    Not knowing all the details, I would have to agree with your customer. A concentricity tolerance of .008 means your tolerance zone is .008 in diameter and that the two axis must be no more than .004 apart. If the TIR is .010 then the axis are .005 apart. Of course we have to assume here that...
  3. grvldrvr

    Y14.5 Feature Modifier Default

    At the risk of answering my own question, I am looking for some reassurance that I am making the correct interpretation of the standard. For tolerance of position, beginning with the 1982 revision of ANSI Y14.5M, it is my understanding that in the absence of a material condition modifier in the...
  4. grvldrvr

    Audit, Heat Treat Process, SAE AMS2759

    I am tasked with writing a process audit checklist for heat treating, specifically SAE AMS2759 as well as AMS 2750 for pyrometry. Is there a source for a generic audit checklist that could be used (or modified) in order to evaluate potential heat treat processors? Thank you, smr
  5. grvldrvr

    sheet metal drawing notes

    Or perhaps, "INSTALL THREADED INSERTS PER THE MANUFACTURER'S INSTRUCTIONS AFTER FINISHING." (Are you installing per the manufacturer's instructions or finishing per the manufacturer's instructions?)