  1. goncetra

    Ultrasonic concrete testing

    Sometimes it is not easy to detect the P-wave because these waves carry little energy, most of the ultrasonic energy is propagated as R-waves. You can avoid this problem by using a through transmition configuration.
  2. goncetra

    Ultrasonic concrete testing

    usually, high w/c ratio when concrete is overfinished can lead to this results. It may be possible that you are not catching the P-wave and the unit detects the R-wave, which is 60% slower than the P-wave.