Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by fnunez

  1. fnunez

    Nitrogen velocity through steel pipe (500 psig)

    Thanks for the answers, API RP 14E have information like Crane but the difference that API rP 14E works with Qg gas flow rate expressed at 14.7 psig and 60° F; not sure why, but I guess that if I work with one of this expressions at the last I will have to convert this Qg to operation...
  2. fnunez

    Nitrogen velocity through steel pipe (500 psig)

    I've read the article, but I don't find the answer it's refered more for liquids. I want to design a nitrogen pipeline (-astm a312_), also I've read Crane the chapter about principles of compressible flow and said that the maximum possible velocity in the pipe is sonic velocity. So in order...
  3. fnunez

    Nitrogen velocity through steel pipe (500 psig)

    I'm designing a Nitrogen distribution system that is going to fill a pressure tank (500 Psig), so I need to know the recommended/allowed velocities that I should consider through the steel pipe and if you can refer a Standard or book that talks about it. Thanks in advance. Fernando
  4. fnunez

    Nitrogen pipeline / surge tank / ASME B31

    Flowrate no determined yet, I've just taken these project, I have tank's plans, the transient study where I find the flowrate on water pipeline, but not sure yet the N2 flowrate but I'm thinking to calculate from the tank volume, and when the system is activated, means when it is a critical...
  5. fnunez

    Nitrogen pipeline / surge tank / ASME B31

    Thanks for all the answers , @BigInch as you said certainly it's closer to an auxiliary system, a N2 supply for the surge system (surge tank). Apologyze, may my english wasn't clear enough, it's why I use the word pipeline, but in fact it's going to be a small supply station, closer to the...
  6. fnunez

    Nitrogen pipeline / surge tank / ASME B31

    I thought that as a b31.8 is for Gas transmysion and distribution piping system could be suitable for my purpouse, but I read in the code that :"802.12 This code does not apply to: (d) piping in oil refineries ... , industrial plants, or MINES ." Attaching again the picture. Thanks!
  7. fnunez

    Nitrogen pipeline / surge tank / ASME B31

    Sorry, If Im not explained as well, the pipeline that I want to design is the Nitrogen one, not the water pipeline. I'm attaching a sketch, about my 2 enquiries, first Which code about Nitrogen pipeline design is proper to use? and 2nd if you know some NFPA or safety code about distances...
  8. fnunez

    Nitrogen pipeline / surge tank / ASME B31

    In order to avoid water hammer effect on a water pipeline a customer installed 3 surge tanks that will be filled by nitrogen, it's located in a mine over a 4500 meters above sea level. There are 2 questions, I have to design the pipelines that goes through each nitrogen group of cylinders to...