  1. fadi123

    Required Motor Size (KW)

    Thanks Artisi, 1. The units that I used are : Q = m3/hr & H in meter to get the power in KW. 2. I use the H & Q at the duty point
  2. fadi123

    Required Motor Size (KW)

    I always depend on the following equation in calculating the required KW for the motor of the pump (Pumped Fluid : clod water): KW (Absorbed power) = (H x Flow)/ Pump Eff. x 367 Motor power = P abs. X Motor Eff. Then I check with the suppliers the availabe motor size that close to my...