Thanks RAYC1.
I notice that in the STAAD.Pro V8i (20.07.06.34) help file it still says the same thing for inactive members which it says in STAAD.Pro 2006.
The exact wording is "The INACTIVE MEMBER command should not be used if the MEMBER TENSION/COMPRESSION command is used"
Is the help file...
In the STAAD help files it states
"TENSION / COMPRESSION commands should not be specified if the INACTIVE MEMBER command is specified"
Can someone please clarify does this mean that you can't run an analysis if it contains these two commands at all or does it mean that you just can't use the...