Dear Friends,
Thx for your reply.
Client wants API 6A design code for choke but wants to use 4130 material for forged body & bonnet.
I can use API 6A annex G for high temp. design but I am not sure that i can use 4130 material for ASME B16.5 flange.
Kemlesh
HI Friends,
one of client is requesting to use AISI4130 for valve body & bonnet.
Temperature is high as 200 Deg C.
I have checked B16.5 for flange but I could not found AISI4130 material for use of flange.
is it acceptable to use AISI4130 material ? and where can i find those point for refer.
Hi Edstainless,
Great Thx.
it is good information for me.
just one question that all those grade has been followed by any international standard?
Like ASTM or other....?
Kamlesh
HI Friends,
I am working in choke valve industry.
Mostly , tungsten carbide has been used for choke valve trim.
Is there any international standard for tungsten carbide's different grades in which i can found chemical as well as mechanical properties.
Kamlesh
Hi Friends,
I am seeing that mostly choke valve which has been used on wellhead are angle type body choke valve.
Is there any benefit to use angle type choke body for choke valve design?
Dear Friends,
I am aware about physical properties of Tungsten carbide like Hardness, density , T.R.S, porosity , Fracture toughness.
But My one client is asking about Impact result and one condition is that 400 j impact value of Tungsten parts.
I am not aware and never face impact test of...
Dear Friends,
i have taken reference of ASTM 29/ ASTM 434 & DIN 1.7218 for AISI 4130
In DIN 1.7218 , i have got chemical & physical property both
In ASTM A29, i have got chemical property & ASTM A434 , i have got physical property.
But My question is that In all above standard , They have...
Hi frd,
My one of client has given process data and choke valve size, flow rate, pressure drop,temp for four different flow rate, pressure drop , temp. condition.
I have got CV from above data . But they wrote that " Please provide Tapered size calculation in graphical and tabular format...
Thank you friends.
I used Graphoil stem seal in one of Globe valve with 10000 PSI.
But at the stage of proto type of Globe valve. valve stem has been jammed. it was because of much force on Graphoil stem seal. and if i m going to loose force, leakage has been started.
SO i do not know what...
Hi Friend,
Thx for giving your valuable comments.
Dear JBECKHOU, i m not sure PEEK seal will work at high pressure. it will be gone after few months of use of check valve.
I have attached figure here. almost all thing improve.but i could not judge that how can prevent the leakage at low...
HI Israelkk,
Agree with your comments. yes. Peek seal will not work at high pressure. Metal to metal seal should be.
I am working on check valve which is spring loaded and metal to metal seal. i am modifying some parts . now it is good to prevent on leakage at high pressure & little on low...
Dear Sir,
In my above question ,
I said . it is working well at high pressure. only fail at low pressure seat test.
On my view , it should be work. but i can not judge that it is working well on high pressure & do not work on low pressure. so what is the possibility for failing at lower...