    I have a DP that is used to read Level in a scrubber. The scrubber has a demister somewhere around the top and from time to time It gets...
    • IMG_4537.jpeg
  • EEENGRX
    EEENGRX replied to the thread Pump Remote Start.
    One thing is to wire a momentary switch to M1, that’s the remote start on the control loop. Then no matter if you loose DCS or not ,it...
  • EEENGRX
    EEENGRX replied to the thread Pump Remote Start.
    LOL..I completely understand your point and I do have the history of the actual running conditions. This motor was designed with no...
  • EEENGRX
    EEENGRX replied to the thread Pump Remote Start.
    Great insight. What about putting an interposing Relay in the START circuit . The primary function will be to close the circuit and...
  • EEENGRX
    The schematic above has to be automated. What would be the best two options to put a START relay in the Bucket for pump remote start...
    • IMG_4216.png
    • IMG_4215.png
  • EEENGRX
    EEENGRX replied to the thread Pump Automation.
    Yes , I was able to solve the priming issue and it’s now working fine.. self priming
  • EEENGRX
    EEENGRX replied to the thread Pump Automation.
    Thanks I have just cracked the puzzle as to why it wasn’t priming. Pump is self priming as we speak and I have programmed it to...
  • EEENGRX
    EEENGRX replied to the thread Pump Automation.
    Start/stop is local. There is a low level cut off for motor. And it has to be manually primed for each start when it gets to a certain...
  • EEENGRX
    EEENGRX replied to the thread Pump Automation.
    Seen ?
  • EEENGRX
    EEENGRX replied to the thread Pump Automation.
    • IMG_3903.jpeg
  • EEENGRX
    EEENGRX replied to the thread Pump Automation.
    The pump is there. The waste water goes into the sump and when it gets to a certain level. Pump is turned on and when level gets to a...
  • EEENGRX
    EEENGRX replied to the thread Pump Automation.
    This is how the flow goes. How do you implement your deliberate priming of pump based on your suggestion?
  • EEENGRX
    EEENGRX replied to the thread Pump Automation.
    • IMG_3903.jpeg
  • EEENGRX
    EEENGRX replied to the thread Pump Automation.
    So the pump motor is already wired to DCS and there is a Radar Level transmitter to monitor Sump Level. I think I can just program the...
  • EEENGRX
    EEENGRX replied to the thread Pump Automation.
    good idea. i incline to prime before each start wether it is needed or not and also have a foot valve