I am trying to get 1 broadband vibration requirment which will encompase both the broadband and narrowband rotary requirements in 810-F. Instead of running two tests, one random and one sine.
The Miles equation requires knowledge of the transmissibility and resonant frequency (i missed the fn...
OK, I know this has been debated before, but I never really got a solution from the previous threads.
Problem statement:
I have an electrodynamic shaker capable of applying only broadband random vibration 5-2000 Hz (hypothetical).
I would like to apply the MIL-STD-810F endurance vibration for...