Dear All:
Further to your replies, we carried out multilayer diffusion simulations for hydrogen at 100 bar pressure and 298 Kelvin. We simulated the following configurations:
1. 10 mm glass reinforced polyamide on top of 12.7 mm
stainless steel (16 inch diameter pipeline).
2. 10 mm glass...
Dear all:
I am currently in the process of setting-up simulations for retrofitting of a natural gas pipeline for hydrogen transport. The operating conditions will be 100 bar hydrogen pressure, temperature -50 to + 50 degrees Celsius.
Because of the embrittlement of stainless steel (e.g. 304...
Dear all:
I am currently in the process of setting-up simulations for retrofitting of a natural gas pipeline for hydrogen transport. The operating conditions will be 100 bar hydrogen pressure, temperature -50 to + 50 degrees Celsius.
Because of the embrittlement of stainless steel (e.g. 304...