  • D
    Yes You answered this...5.1 5.4.2 If you don't meet 5.4.3.2 or 5.4.3.3 RT is required. Table 6 may clear things up for you.
  • D
    David3399 replied to the thread Opening on Blind Flange.
    Correct. Opening size and spacing limits of UG-36 apply or use UG-39 for reinforcement.
  • D
    The answer to your question is simple..... Yes. Why they would want to is harder to decipher. Way easier to roll 75mm vs 140mm.
  • D
    David3399 replied to the thread Opening on Blind Flange.
    The Code allows B16.5 flanges to be used at the pressure/temp ratings of those standards without additional calculations. B16.5 allows...
  • D
    David3399 replied to the thread Opening on Blind Flange.
    It's telling you exactly what I said...it's no longer a blind flange. Even though the openings are exempt from reinforcement it needs...
  • D
    David3399 replied to the thread Opening on Blind Flange.
    I would no longer call this a blind flange...now is a bolted cover and needs to be designed to UG-34.