I appreciate your reply, Latexman.
I just heard about required steam flow rate to Unit A is 90,000 lb/hr. So,
The problem statement we are trying to determine is: we need 90,000 #/hr of 400 psig steam, will it fit through a 10” line, what is the anticipated velocity and will it exceed some...
Thank you for your time.
There is a 12" Schedule 40 piping existing and currently supplying to Unit B (to existing process units) with 400 psig steam. We are planning a new Unit A which is trying to use some of this OSBL (out side battery limit of process units) steam supply. There is a 10 inch...
I am trying to calculate maximum velocity/ flow rate (choked) of 400 psig steam in a planned 10 inch Nozzle for unit A steam supply from an existing 12 inch 400 psig steam supply line to unit B in Tee connection.
I am using 400 psig inlet/outlet steam pressure in 12 inch steam supply existing...