Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by Bullpen

  1. Bullpen

    Bunker 'C' Concern

    In our system there is 1 line coming from the heating plant(no return line). When the bunker enters our plant it is pumped by positive displacment pumps through an HTHW heat exchanger which raises the temp to 275 deg f. then to the indurating furnaces through a loop by which unused fuel is...
  2. Bullpen

    Bunker 'C' Concern

    In our process we receive Bunker 'C' from our heating plant at about 150 degs F. It is further heated through heat exchangers to 275 degs F. before it is atomised in our burner guns in the induration furnace. Normal shutdown of this system would require light fuel to be added to the lines to...