What materials are generally used for the design of ultra-supercritical high-pressure boiler tubes?
Ultra-Supercritical (USC) high-pressure boiler tubes need to withstand extremely high temperatures and pressures (usually pressures exceeding 27.5 MPa and temperatures reaching 700°C or above), so...
1. I am designing a RC support (see attached) for 600 dia. ductile iron carrying sewage water from pumping station. Mostly pipe is aligned upward on embankment at slope 8%. I understand that for before casting concrete foundation, we would need to place the pipe on temporary support. Can anybody...
Per ASME B31.3, the design pressure must account for the highest pressure the system could experience, including transient conditions or safety valve settings. The safety valve setting of 290 bar represents the maximum pressure the system is designed to handle before the safety valve activates...