Kinda what I was thinking SlideRule, thanks.
Btw, yes, that is the valve. The actuator my case would be propotionally larger piston type due to a torque requirement and there would be an extended bonnet that moves the actuator out 33.5".
Does anyone know an appropriate method to support an extended bonnet valve with an actuator in a plants piping? I have sized a 12"-600# Fisher type A11 cryogenic trip valve with an extended bonnet (33.5") that has a 700# actuator hanging off the end.
Our customer is requesting our support...