For confirmation, Newman's book provides a lot of the answers everyone in my office has been trying to get PEMB salesmen to answer. Industry details, cost efficiency, and structural contract document requirements. Three architects have stopped by my desk to check it out already, and am hearing...
"Jack of all trades, master of none" It is mainly due to the breadth of the information. They expect you to be a master of 7 completely different subject areas whereas other disciplines are much more focused...on the test and in practice. In 4 years of experience you're either going to be...
That is really good advice and it does help me, though I cannot limit my structural contract because I work beside an architect under one roof.
My question has to do more with how to detail a lot of these different conditions. Basically I need something to help me with details. If you design...
I work at an A/E firm and it usually comes up once or twice a year that some architect wants to make a PEMB fancy by making an odd column layout, cladding it with brick, adding mezzanines, adding cantilevers, and using odd roof pitches. For example, an architect came to me today wanting to know...
Interesting question came up today. Have a 3" diameter solid dowel pin connecting two elements that have 200 kip axial load in them. The fabricator is asking wether or not steel A4150 is acceptable. Has anyone ever heard of this stuff and/or run into a similar situation? How do you evaluate...
Yea, I just want the strength of the threads. Not the required torque. 200kips acting only on 3" of threads is questionable in my mind. Cross section of the bolt/rod is more than enough.
I dont know why AISC doesnt incorporate this into the book since it would apply to stripping leveling...
Sorry, thought you meant the old green book. Yes, I looked into that table in the LRFD 3rd ed and it's the same.
Do you apply rupture limit states to thread area? I want to determine if the bolt will strip out of the 3" deep tapped hole.
I'm looking at a 10" diameter tower crane tieback with an in line adjuster composed of a 4" diameter threaded rod that screws into 3" thick end plates. So the tieback looks like this:
||||||||||||||--|||||
The -'s represent the threaded rod
This rod will therefore take all of the 200kip of...
I'll just point out that APA's squeak free guidelines dont include screws. They focus on the details of the panel joints, glue application, glue type, and give basic nailing patterns.
I would guess the ductility of the system is affected more by the glue than the nails.
Just need to add an important exception to your suggestion StructuralEIT. If you choose to tack weld a nut to the end of the rod, you cannot use a high strength rod due to its brittleness. This is why I always suggest just using a jamb nut.