  1. Bilsko

    Combined Cycle Power Plant - GT and ST power output

    MisterDonut: Thanks for confirming - I aslo plugged the data into the Katmar software and came up with just about the same figures. RMW: You're right it is definitely a confusing set of details. All of this equipment that I'm describing (GT, HRSG, BPT) would be new equipment. I'm intrigued...
  2. Bilsko

    Combined Cycle Power Plant - GT and ST power output

    racookpe1978 - I don't think that's the backwards approach at all - in fact that's precisely what we're proposing. The gas turbine alone (7500kW nominal, maybe up to 8400 on really cold days) is sufficient to meet most of their winter/shoulder baseload. From the calculations that I've done...
  3. Bilsko

    Combined Cycle Power Plant - GT and ST power output

    MisterDonut, Thanks for the reply - good to know that we shouldn't expect multiple, seasonal output profiles form a single HRSG. There are a few reasons why we're trying to avoid electric-only output from the turbines and package boilers for steam: -In this particular case, the thermal is...
  4. Bilsko

    Combined Cycle Power Plant - GT and ST power output

    I don't want to hijack this thread, but my questions are pretty similar to Felipe's, so hopefully I can draw out a bit more help from the forum. I'm running a performance/finanical assessment of an onsite setup for a college campus in the Mid-Atlantic. Our assessment is trying to determine the...