Good evening to All
We are on the point to perform the commissioning of a new Gas on Line Blending Unit. The unique aspect of this unit, all piping have a length of about 2 km, pipings are only "one way" route from one tank to another tank. The end user expects for a good mechanical cleaning of...
Hi Mike
I come back to my dilemma? What we could do to prevent that premature failure? Could we complain to the equipment design?
Many thanks for your comments, I noted all
Best regards
Aurel Mares
Hi Tmoose and thank you for your great feedback
We measured velocity over all vibration on the failed bearing house located next to the driven belt. Of course we measured and the opposite bearing vibration and noticed the noise, but was not detected any problem with the second bearing. Oil...
Hi to everyone
In one of our project we have installed a gas rotor blower belt driven, suction pressure 0.4 bar g, discharge pressure 0.8 bar g, capacity maximum 350 cubic meter/h. After about 2000 hours it was noted an unusual noise, even vibration level was in the same range since start-up...