JStephen and AK8824 are both right. Also I would like the member’s opinion on the following:
1) Equations under clause 5.11.2: The equations should have been on uplift rather than on moment (60% of uplift due to MWH + 60% of uplift due to PWR + uplift due to internal pressure < 66% of W2)...
UMR,
A partial stiffening ring does not seem to be an answer to your problem. The best solution is to use tailing beam (2 point) as shown in "Base ring stiffening Configuration", page 406 of ‘Pressure Vessel Design Manual’ by Dennis R. Moss (3rd Edition).
The stress analysis of base ring with a...