A Krautkramer MIC 10 On Site Hardness Testing Device according to Ultrasonic Contact Imedance ASTM A 1038 was used to get the hardness values from the surface of the material.(the diamond indent in the material surface is electroncially measured. vickers penetration with indendation evaluation...
It is right, In-situ hardness testing on service-exposed equipment is at best for qualitative purposes. With refrence to which values to be verified to check the in service obtained values are
refering to what condition of the equipment?
Reformed Gas TO Synthesis Gas Convertor Reactor - Shell Plate SA 516 Gr 55 Material - Weld Hardness 243 Brinells Hardness / HAZ 226 Brinells Hardness. ASME SEC II Part C (welding consumables)SFA 5.1 Specification for carbon steel electrodes for Shielded metal arc welding dosen't mention WELD &...