we made laser alignment last year. 208 hz was occur after bearing unit changed ( 2 months ago ).
Last week total RMS app 7 mm/s , after system stop for cleaning than start RMS app 10 mm/sn V direction. than we make rigid support some area under base frame. This fan on the spring. And 1x 2985...