iam working in a vacum salt plant and we need to generate hot air through multi stage heat exchanger between air from a blower and heat from direct flame using a burner
i want to decide what burner i should use so i need to know how i can calculate the heat needed to heat 154 metre cubic per...
metengr
my application is that iam intending to make a huge silo to store ready made salt in it.
this silo will store arround 45 tons of salt
it is so economically to make the silo from carbon steel grade 37 and clade it with stainless steel 304 to prevent the silo from corrosion
so, what is the...
what are the best ways of welding a sheet of steel thickness 10 mm with a sheet of stainless steel 304 thickness 2 mm?
the sheets dimensions are 14 m * 4 m
is the riveting a better way than the welding
iam working in a salt manufacturing plant and there is a part in the process we use steam ejector to create vacum but i donot know a lot of information on this part and how it is designed and works
so....
can any one help?
thanks
hi all,
if i have a boiler that works under pressure of 10 bar to produce 10000 kg of saturated steam per hour and it works by natural gas
1 m^3 natural gas = 9750 kcal
and the heating value of it isa 980 to 1100 btu/ft^3
what is the amount of gas i need per hour?
and what is the amount of...
hi all
i thank you all for the contribution in solving my problem
and i think i have solved it now
but i would like to ask what else info should i give to you to be full detail??
dear frank
thank you very much...
i forgot to tell that the pipe is made of upvc,
and the velocity is not that important iam only concerning about flow and the slurry is cold
ahmed assem
dear all
iam so much confused of how much could be a pipe diameter to permit a flow rate of 400 lit/min of slurry from one tank to another, the flow by gravity, and the level differnce betwee the 2 tank is 1 metre and the length of the pipe is 10 metre