Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by 6240

  1. 6240

    How do I calculate the corrosion rate

    DEar Roger, You have the worst scenario possible: seawater, scale inhibitor, carbon steel, and even different temperature (this is a killer). I don't know formulas for calculation but I would suggest you replace your carbon steel piping with stainless steel (I think the 400 series is for...
  2. 6240

    SS groundwater well screen

    I want to thank the people that tried to answer my question. However, I did not get the info I needed. My personal problem with the set up is that I have never heard anybody install cathodic protection for the stainless steel (SS 304) casing and screen of a groundwater monitoring well. I hoped...
  3. 6240

    corrosion rate of steel in clay soil

    Corrosion underground is very complicated and unpredictable process. It depends not only on the chemistry of the soil and water, but also on the bio-processes that may be occurring. In clay soils the bio-corrosion is slowed down very much unless close to the surface. The corrosion will...
  4. 6240

    SS groundwater well screen

    I have some people that want to install impressed current cathodic protection for groundwater monitoring wells with stainless steel screens. However, the monitoring wells are supposed to monitor for metals. I think that many of the metals in the groundwater will be plated on the anode or...