×
INTELLIGENT WORK FORUMS
FOR ENGINEERING PROFESSIONALS

Log In

Come Join Us!

Are you an
Engineering professional?
Join Eng-Tips Forums!
  • Talk With Other Members
  • Be Notified Of Responses
    To Your Posts
  • Keyword Search
  • One-Click Access To Your
    Favorite Forums
  • Automated Signatures
    On Your Posts
  • Best Of All, It's Free!

*Eng-Tips's functionality depends on members receiving e-mail. By joining you are opting in to receive e-mail.

Posting Guidelines

Promoting, selling, recruiting, coursework and thesis posting is forbidden.

Students Click Here

Safety Relief Valve engineering (PSV) FAQ

Safety Valve Calculations

Why is it so difficult to meet the inlet/outlet pressure drop limits for some PSVs and not others? by don1980
Posted: 30 Jan 17 (Edited 11 Jun 20)

Why do we inherently have difficulty meeting the pressure drop limits when using some particular PSVs and not others? This is an unintended consequence which stemmed from the original creation of API 526 (API orifice sizes, and the PSV bodies into which these orifices are installed). As the orifice sizes increase, the bodies sizes (and their connection sizes) don't increase proportionately. The result is that some orifices (particularly the larger ones) are too big for the PSV body/connections. That is, some orifices allow a flowrate that inherently causes too much pressure drop for the PSV's inlet and outlet size.

See the table that I've attached. Specifically look at the ratios for inlet-area/orifice-area and outlet-area/orifice-area. This explains why you almost never have pressure drop problems with 1D2 PSVs, and why you almost always have pressure drop problems with larger PSVs like 4P6 and 8T10. When up-sizing the inlet and/or outlet piping isn't enough to solve a pressure drop problem, the most cost-effective solution is to restrict the lift of the PSV. Effectively, this allows you to reduce the rated capacity (the flowrate used to calculate the pressure losses) for the PSV. Since pressure drop increases proportionately to the square of the flowrate, it doesn't take much of a flow reduction to make a big impact on the pressure drop. Obviously, the reduced flowrate must be high enough to satisfy the required flow. Contact your PSV supplier when implementing this option. Based on your required flowrate, they will determine the necessary lift reduction, and they will supply the necessary part which is installed by a professional valve shop. The vendor will also provide the new rated capacity for this restricted-lift PSV.

http://res.cloudinary.com/engineering-com/image/up...

Back to Safety Relief Valve engineering (PSV) FAQ Index
Back to Safety Relief Valve engineering (PSV) Forum


My Archive


News


Close Box

Join Eng-Tips® Today!

Join your peers on the Internet's largest technical engineering professional community.
It's easy to join and it's free.

Here's Why Members Love Eng-Tips Forums:

Register now while it's still free!

Already a member? Close this window and log in.

Join Us             Close