INTELLIGENT WORK FORUMS
FOR ENGINEERING PROFESSIONALS

Member Login

HANDLE


PASSWORD
Remember Me
Forgot Password?

Come Join Us!

  • Talk With Other Members
  • Be Notified Of Responses
    To Your Posts
  • Keyword Search
  • Turn Off Ad Banners
  • One-Click Access To Your
    Favorite Forums
  • Automated Signatures
    On Your Posts
  • Best Of All, It's Free!

E-mail*
Handle

Password
Verify P'word
*Eng-Tips's functionality depends on members receiving e-mail. By joining you are opting in to receive e-mail.

Partner With Us!

"Best Of Breed" Forums Add Stickiness To Your Site
Partner Button
(Download This Button Today!)

Member Feedback

"...I just wanted to say that you guys RULE, a million thank you's to whoever created, and/or manages this site. KEEP UP THE GOOD WORK..."

Geography

Where in the world do Eng-Tips members come from?
shipmate (Marine/Ocean)
23 Jan 03 13:31
The US tends to use reactors in their tap changer diverter configurations, whereas a large part of the rest of the world uses switched resistors. As a non-US electrician, what are the benefits and drawbacks of using reactors, and is this as a result of the common US practice to tap on the low voltage side of the transformer, against the neutral end of the high voltage side in other parts of the world. What is the typical maintenance program for the reactor version?
Eng-Tips Forums is Member Supported. Click Here to donate.
DougMSOE (Electrical)
24 Jan 03 8:29
The reason to go with the reactor based system is to eliminate the "change in current with respect to time (di/dt)". The resistor type is usually used to "clanp" the voltage to a definite E/R ratio. I would offer that some of these devices also use a thristor based system, typically on large inductive loads such as induction furnaces.
stevenal (Electrical)
28 Jan 03 15:27
I'm in the US, and only spec high speed resistive or vacuum diverter LTCs. Maintenance is the issue. Get rid of or reduce arcing, and maintenance intervals go way up. Reactive LTCs require frequent oil filtering and contact replacement.
electricuwe (Electrical)
2 Feb 03 6:23
I found a good explanation for the different approach in the US and elsewhere in the following book:

Laughton, M.A.; Warne, D.F.: "Electrical Engineer's Reference Book", 16th edition, Oxford, 2003

US engineers tend to specify a large number of taps with small tap steps. With the inductor approach the bridging position can be used as running tap.

Start A New Thread

Posting in the Eng-Tips forums is a member-only feature.

Click Here to join Eng-Tips and talk with other members!

Promoting, selling, recruiting and student posting
are not allowed in the forums.
Posting Policies

LINK TO THIS FORUM!
(Add Stickiness To Your Site By Linking To This Professionally Managed Technical Forum)
TITLE: Electric power engineering Forum at Eng-Tips
URL: http://www.eng-tips.com/threadminder.cfm?pid=238
DESCRIPTION: Electric power engineering technical support forum and mutual help system for engineering professionals. Selling and recruiting forbidden.

 
Close Box

Join Eng-Tips® Today!

Join your peers on the Internet's largest technical engineering professional community.
It's easy to join and it's free.

Here's Why Members Love Eng-Tips Forums:

Register now while it's still free!

Already a member? Close this window and log in.

Join Us             Close